Please enable JavaScript to view this site.

MaxxECU Documentation

MaxxECU GEN2 only, feature not available on the MaxxECU GEN1 platform.

 

Output function for generating engine-synchronized pulses, supporting configurable pulse angles and durations for DI pumps and other applications.

 

 

Sync Pulse Output X

 

Description

Assign a descriptive name to the output or function. This name is displayed throughout MTune PC-software and MDash Android app, making it easier to identify and distinguish the function in configuration menus, monitoring views, logs, and dashboards. Use clear, meaningful names.

 

Output enabled

Enables or disables the output. When Disabled, the output is forced to its inactive condition while all settings remain available for configuration and testing without affecting the physical output. For inverted outputs, the physical output will remain active when disabled, as the activation conditions are treated as false.

•Enabled - The output operates normally according to its configured conditions.

•Disable - The output is disabled while all settings remain editable. The activation conditions are forced false, meaning inverted outputs remain physically active.

 

 

output settings

 

Output polarity

•Idle off - Output is OFF when inactive and switches ON during the pulse.

•Idle on (inverted) - Output is ON when inactive and switches OFF during the pulse. Used for active-low signals.

 

Pulses per  cycle

1-12 pulses per 720 degrees of crankshaft rotation can be generated. Either based on the cylinder count and engine base firing order configuration, or with per-output-set base angles for each pulse in crank angle after TDC of cylinder 1.

Any even or uneven output pattern may be used.

Note: The pulse outputs are not affected by fuel or ignition cuts. The pulse outputs start as soon as the trigger system is in sync, and at the start of the first on event after sync.

 

start angle direction

•After base angle - Pulse starts at the configured angle after the base angle.

•Before base angle - Pulse starts at the configured angle before the base angle.

 

duration mode

•time - Pulses of 0.001ms to 32ms can be set. At 0 ms, no pulse is output. pulse duration is measured from the ON edge, and the pulse completes even if synchronization is lost or the engine stops. A pulse duration of zero skips the pulse completely, allowing individual events to be suppressed.

•angle - An angle of 0.1 to 720 degrees can be set. 0 degrees means no pulse is output. Pulses may overlap, in which case the output stays on until the overlapping condition is removed. In case of sync loss, the output will revert to its idle state at the theoretically calculated off-point.

 

Offset angle table

Specifies the offset angle (degrees after/before) the base angle.

Note: Negative ON angles are supported.

 

duration time / angle table

Specifies the time or angle for the above duration mode.