Please enable JavaScript to view this site.

MaxxECU online help

Navigation: MTune Settings > Limits

User Cut tables

Scroll Prev Top Next More

User Cut tables can be used to limit engine RPM, or just cut fuel/ignition under certain condition.

Note: The normal way of limit the engine RPM is by using the normal Rev limit.

 

 

user cut table

 

user cut mode enable

Specifies the enable mode of the function.

Disabled - The user cut table function is not active.

enabled by digital input - Enabled when the digital input function User Cut Table X, enable is active.

always active - The User cut table functions is always active.

 

Description

Name/description of the user cut table.

 

user cut method

Specifies the engine cut method.

Cut fuel - Cut fuel using the table %.

Cut ignition - Cut ignition using the table %.

Cut fuel+ignition - Cut fuel AND ignition using the table %.

 

 

Example

 

clip1357

A simple example using the User Cut Table feature, which in the above example cut both fuel and ignition when the battery voltage gets to high.