Please enable JavaScript to view this site.

MaxxECU online help

Used to generate slow or fast pulse trains, for example be used to control RC servos or oil injection pumps.

 

 

User pulse/frequency output

 

Enabled

Enable or disables the output function.

 

Description

Gives the output function a name within the whole system.

 

 

Activation condition

 

on condition

Specifies how to enable the output function.

Always active - Always active, when enabled.

user condition - Activate based on user variable condition, see below.

 

Variable

Activate the output function based on user variable condition. Only visible when the above activation condition is set to user condition.

 

 

pulse width table

 

Pulsewidth mode

The range of the pulsewidth. Set depending on if a slow or fast pulsed output is needed.

Pulsewidth, ms, 0-30ms, 1µs resolution

Pulsewidth, sec, 0-30s, 1ms resolution

 

 

Frequency table

 

frequency mode

The range of the frequency. Set depending on if a slow or fast pulsed output is needed.

Frequency, Hz, 0-3200Hz

Frequency, /min, 0-3200 pulses/min